Control IntelliCraft
From PDF drawings to structured engineering data
Control IntelliCraft (CIC) turns a project's engineering drawings and lists into structured, traceable data. Instrument tags, junction boxes (JB), instrument cables and marshalling cabinets (MC) are detected in PDF drawings with OCR and machine learning, then matched against the I/O list. I/Os are allocated to cabinets automatically and in an optimized way. Processing runs on a GPU server inside your organization.
Capabilities
Tag, JB, cable and MC detection
I/O tags, instrument cables, junction boxes and marshalling cabinets in PDF drawings are found and classified with OCR and machine learning.
Matching with the I/O list
Each tag is matched to its row in the I/O list and Excel lists, and mismatches are reported precisely.
Automatic, optimized I/O assignment
I/Os are assigned to modules and cabinets automatically and in an optimized way, taking into account channel availability, spare capacity and the segregation of intrinsically safe (IS) circuits.
Full traceability
Every tag from the PDF drawing to its Excel row, with cabinet, board and channel.
Output ready for review
An annotated PDF, an Excel file, a JSON report for other software and a ZIP package, ready for the engineering team to review.
Multi-vendor control system projects
CIC supports control-system design optimization across different vendors, working from the project's engineering drawings and lists.
Inside your organization
Processing on an in-house GPU server, with several users at once; no drawing leaves your organization.
Spare and hot-spare management
I/Os are allocated to cabinets in an optimized way, with spare capacity (free channels kept for later expansion) and hot-spare capacity (spare channels installed and ready to use) taken into account automatically.
Two modules
- 01
Module 1: JB detection
The PDF drawing is uploaded, JB and MC boxes are found, tags are read with OCR and matched to the I/O list, and the result is marked on the PDF and written to Excel.
- 02
Module 2: I/O assignment
The I/O list, the cabinet layout and channel capacities go in; I/Os are allocated, junction box by junction box, to modules on IS and NIS rails, keeping spare and hot-spare capacity, and Excel gives the assignment, an input report and statistics.
Let's start with a pilot in your plant
Pick one concrete problem in your process. We'll show, in your own environment, what value industrial AI creates.
sales@aryavakav.com+98 21 2637 4300 · +98 21 2637 4301